click
image for
pdf-download
|
|
|
Type |
TA134 |
TA200 |
Main features |
|
|
Supply voltage |
24, 48, 115, 230 VAC,
12...30 VDC |
24, 48, 115, 230 VAC,
24 VDC |
Power consumption |
5
VA, 4 W |
6 VA, 4 W |
Sensor supply
12...26 VDC |
Max. 60 mA |
Max. 100 mA |
Inputs |
A,
B, 3 control inputs |
F1 |
Input frequency |
25 Hz, 40 kHz |
25 Hz, 40 kHz |
Outputs |
Electr.
or relay |
-- |
Interface |
RS485 |
-- |
Display |
LCD,
6-digit |
LED,
6-digit |
Front dimensions |
48 x 48 mm |
96 x 48 mm |
Particularities |
Background
illumin. |
-- |
click
image for
pdf-download
|
|
|
Type |
TA201 |
TA202 |
Main features |
|
|
Supply voltage |
24, 48, 115, 230 VAC,
24 VDC |
24, 48, 115, 230 VAC,
24 VDC |
Power consumption |
6 VA, 4 W |
7
VA, 5 W |
Sensor supply
12...26 VDC |
Max. 100 mA |
Max. 100 mA |
Inputs |
F1,
F2/Start, Stop |
F1,
F2/Start, Stop |
Input frequency |
25 Hz, 10 / 40 kHz |
25 Hz, 10 / 40 kHz |
Outputs |
-- |
Electr. and relay |
Interface |
-- |
RS232 / 422 / 485 |
Display |
LED,
6-digit |
LED,
6-digit |
Front dimensions |
96 x 48 mm |
96 x 48 mm |
Particularities |
Calculation
functions |
Calc. funct.
and limit value |
click
image for
pdf-download
|
|
Type |
TA204 |
Main features |
|
Supply voltage |
24, 48, 115, 230 VAC,
24 VDC |
Power consumption |
6 VA, 4 W |
Sensor supply
12...26 VDC |
Max. 85 mA |
Inputs |
F1, F2 |
Input frequency |
25 Hz, 40 kHz |
Outputs |
Relay |
Interface |
RS422 / 485 |
Display |
LED,
6-digit |
Front dimensions |
96 x 48 mm |
Particularities |
-- |
|
|